Reviews
You might also need
Milwaukee pH55 PRO Waterproof pH & Temperature Tester with ATC
The Milwaukee Waterproof pH55 PRO pH/Temp Tester with ATC is one of our most accurate cost effective, well rounded, rugged and reliable testers in the market featuring dual level LCD readouts, easily replaceable probe and extended pH ranges to meet almost any application. It's simple 1 or 2 point automatic calibration is simple-to-use and offers TWO sets of memorized buffers to select. Ideal for use in aquariums, hydroponics, horticulture, education, pools, beer and many other applications.DESIGN FEATURESFast easy to read results with large digital LCD readout.Extreme pH accuracy to ±0.1 pH with an extended pH range (-2.0 pH to 16.0 pH).Resolution to 0.1 pH.Lightweight and portable.Easy measurement: just place the probe in the sample, gently stir, wait for the stability indication to show a stable reading and then freeze the reading.Simple Automatic one or two-point calibration.2 Sets of pre-memorized buffers.Gel-filled, double junction pH electrode for low maintenance and high performance.Over 300 hours of battery life (batteries included).Fully waterproof to IP65.Replaceable pH electrode Mi56P.SPECIFICATIONSpH Range: -2.0 to 16.0 pHTemperature Range: -5.0 to 60.0°C (23 to 140°F)pH Resolution: 0.1 pHpH Accuracy: ±0.1 pHTemperature Accuracy: ±0.5°C (±1°F)Typical EMC Deviation: ±0.1Typical EMC Temperature Deviation: ±0.3°C (±0.6°F)Temperature Compensation: Automatic from -5 to 60°C (23 to 140°F)Calibration Automatic: 1 or 2 points with 2 sets of pre-memorized buffers (pH 4.01, 7.01, 10.01) or (pH 4.01, 6.86, 9.18)Probe: Replaceable double junction for extended life (Mi56P)Environment: -5 to 50°C / 23 to 122°F; max RH 100%Battery Type: 4 x 1.5V; IEC LR44, A76 (included)Battery Life: Approx. 300 hours of useAuto-off: after 8 minutes on non-useDimensions: 254 × 67 × 47 mmWeight: 99.22 gCARE AND USEAll pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH Tester will give you fast, accurate results for longer.Here are our top four tips. 1. Always store with the cap full of buffer or storage solution MA9015 not water.2. Clean your Tester regularly by soaking in cleaning solution MA9016.3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH sensor.4. Gently stir the Tester in the sample for a faster result.
Milwaukee Storage Solution 230ml
MA9015 is a lab grade electrode storage solution prepared with premium chemicals to improve the performance and extend the life of your pH and ORP electrodes, testers and pens.To ensure a quick response and free-flowing liquid junction, the sensing element and reference junction must not be allowed to dry out. Properly storing your pH electrode in a solution keeps the glass membrane well hydrated which maintains proper function and provides accurate readings.MA9015 also helps keep the junction in your pH and ORP electrode flowing which is critical for fast results.DESIGN FEATURESFundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings.Formulated to minimize organic growth on your electrode.Sealed against light with air tight, tamper proof cap.Factory blended to precise standards in a dedicated, temperature controlled environment.Simply open and add to the cap of your electrode or tester.USE:Replace when it gets dirty or evaporates. It must be always filled up till the mark on cap of the pH-meter.
Milwaukee pH56 PRO Waterproof pH & Temperature Tester with ATC
The Milwaukee pH56 PRO pH and Temperature Tester is our most accurate tester with the ability to easily replace the probe for years of use.DESIGN FEATURES- Fast easy to read results with large digital dual LCD readout- Extreme pH accuracy to ±0.05 pH with an extended pH range (-2.00 pH to 16.00 pH)- Lightweight and portable- Easy measurement: just place the probe in the sample, gently stir, wait for the stability indication to show a stable reading and then freeze the reading- Simple push button, automatic one or two-point calibration with 6 saved calibration points- Gel-filled, double junction pH electrode for low maintenance and high performance- Auto shut off and low power demand for a 300 hour extended battery life (batteries included)SPECIFICATIONSpH Range: -2.00 to 16.00 pHTemp Range: -5.0 to 60.0°C / 23.0 to 140.0°FpH Resolution: 0.01 pHTemp Resolution: 0.1°C / 0.1°FpH Accuracy: ±0.05 pHTemp Accuracy: ±0.5°C / ±1°FpH: Typical EMC Deviation ±0.02 pHTemp: Typical EMC Deviation ±0.3°C / ±0.6°FCalibration automatic, 1 or 2 points with 2 sets of memorized buffers (pH 4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)Temperature Compensation: Automatic from -5 to 60°CProbe: Replaceable double junction for extended life (Mi56P)Environment: -5 to 50°C / 32 to 122°F; max RH 100%Battery Type: 4 x 1.5V; IEC LR44, A76 (included)Battery Life: Approx. 300 hours of useAuto-off: After 8 minutes of non-useDimensions: 7.9 inches × 1.5 inches (diameter)Weight: 3.5 ouncesCARE AND USEAll pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH Tester will give you fast, accurate results for longer.Here are our top four tips. 1. Always store with the cap full of buffer or storage solution MA9015 not water.2. Clean your Tester regularly by soaking in cleaning solution MA9016.3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH sensor.4. Gently stir the Tester in the sample for a faster result.
Milwaukee Cleaning Solution 20ml
Cleaning solution is ideal for cleaning all pH, ORP and TDS meter's probes. To help maintain high performance and accuracy for any electrode, regular cleaning is required to remove the build up of dirt and setiment on the glass or carbon surfaces of a sensing probe. Use M10016B to help extend the life of the meter's electrode. Electrode cleaning solution should not be a substitute for rinse and or storage solutions. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution. Milwaukee cleaning solutions are designed to help you achieve reliable and repeatable measurements while extending the life of your electrode.DESIGN FEATURESFundamental for gently cleaning the electrode between uses and before storage.Sealed against light and air.Ideal for on-the-spot cleaning too.Simply open, insert the tester or electrode into the sachet and gently stir let soak for 15 minutes.